Clamp-on Current Sensor - CLSE-05 Clamp-on Current Sensor - CLSE-05 MG MODEL #: CLSE-05 (Easy-to-install, spring-loaded, clamp-on type) Power Input: 05: 50 A Standards & Approvals: blank: Without CE
Clamp-on Current Sensor - CLSE-10 Clamp-on Current Sensor - CLSE-10 MG MODEL #: CLSE-10 (Easy-to-install, spring-loaded, clamp-on type) Power Input: 10: 100 A Standards & Approvals: blank: Without CE
Clamp-on Current Sensor - CLSE-20 Clamp-on Current Sensor - CLSE-20 MG MODEL #: CLSE-20 (Easy-to-install, spring-loaded, clamp-on type) Power Input: 20: 200 A Standards & Approvals: blank: Without CE
Clamp-on Current Sensor - CLSE-40 Clamp-on Current Sensor - CLSE-40 MG MODEL #: CLSE-40 (Easy-to-install, spring-loaded, clamp-on type) Power Input: 40: 400 A Standards & Approvals: blank: Without CE
Clamp-on Current Sensor - CLSE-60 Clamp-on Current Sensor - CLSE-60 MG MODEL #: CLSE-60 (Easy-to-install, spring-loaded, clamp-on type) Power Input: 60: 600 A Standards & Approvals: blank: Without CE
Clamp-on Current Sensor - CLSE-R5 Clamp-on Current Sensor - CLSE-R5 MG MODEL #: CLSE-R5 (Easy-to-install, spring-loaded, clamp-on type) Power Input: R5: 5 A Standards & Approvals: blank: Without CE
Ethernet Tower Light - IT40SRE-3RYGNND1-M2 Ethernet Tower Light - IT40SRE-3RYGNND1-M2 MG MODEL #: IT40SRE-3RYGNND1-M2 (small size, 40 mm dia., Modbus/TCP, 1 - 5 layers) Lamp Layers: 3: 3 layers Lamp 1 Color: R: Red Lamp 2 Color: Y: Amber Lamp 3 Color: G: Green Lamp 4 Color: N: None Lamp 5 Color: N: None Mounting: D: Direct mounting Design Type: 1: Type 1 Power Input: M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) Options: blank: none
Ethernet Tower Light - IT50SRE-3RYGNND1-M2 Ethernet Tower Light - IT50SRE-3RYGNND1-M2 MG MODEL #: IT50SRE-3RYGNND1-M2 (small size, 50 mm dia., Modbus/TCP, 1 - 5 layers) Lamp Layers: 3: 3 layers Lamp 1 Color: R: Red Lamp 2 Color: Y: Amber Lamp 3 Color: G: Green Lamp 4 Color: N: None Lamp 5 Color: N: None Mounting: D: Direct mounting Design Type: 1: Type 1 Power Input: M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) Options: blank: none
Ethernet Tower Light - IT60SRE-3RYGNND1-M2 Ethernet Tower Light - IT60SRE-3RYGNND1-M2 MG MODEL #: IT60SRE-3RYGNND1-M2 (small size, 60 mm dia., Modbus/TCP, 1 - 5 layers) Lamp Layers: 3: 3 layers Lamp 1 Color: R: Red Lamp 2 Color: Y: Amber Lamp 3 Color: G: Green Lamp 4 Color: N: None Lamp 5 Color: N: None Mounting: D: Direct mounting Design Type: 1: Type 1 Power Input: M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) Options: blank: none
Lightning Surge Protector - MD7TC-FF2 Lightning Surge Protector - MD7TC-FF2 MG MODEL #: MD7TC-FF2 [Lightning surge protector for thermocouple use (ultra-slim)] Shield Terminal (line / earth): FF: Floating / Floating Safety Approval: 2: ATEX intrinsic safety
Lightning Surge Protector - MDK-24 Lightning Surge Protector - MDK-24 MG MODEL #: MDK-24 (Lightning surge protector for standard signal line use)
Lightning Surge Protector - MDM2A-24-M2 Lightning Surge Protector - MDM2A-24-M2 MG MODEL #: MDM2A-24-M2 [Lightning surge protector for standard signal line & pulse use (life monitor, 24 V DC line voltage)] Power Input: M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz)
Lightning Surge Protector - MDM2A-24-P Lightning Surge Protector - MDM2A-24-P MG MODEL #: MDM2A-24-P [Lightning surge protector for standard signal line & pulse use (life monitor, 24 V DC line voltage)] Power Input: P: 110 V DC (Operational voltage range 85 – 150 V, ripple 10 %p-p max.)
Lightning Surge Protector - MDM2A-24-R Lightning Surge Protector - MDM2A-24-R MG MODEL #: MDM2A-24-R [Lightning surge protector for standard signal line & pulse use (life monitor, 24 V DC line voltage)] Power Input: R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
Lightning Surge Protector - MDP-24-1/A33/CE Lightning Surge Protector - MDP-24-1/A33/CE MG MODEL #: MDP-24-1/A33/CE (Lightning surge protector for standard signal line & pulse use) DIN Rail Mounting Adapter: A33: With adapter (model: A-33) Standards & Approvals: UL: UL approval, CE marking
Lightning Surge Protector - MDP-24-1/A33/N Lightning Surge Protector - MDP-24-1/A33/N MG MODEL #: MDP-24-1/A33/N (Lightning surge protector for standard signal line & pulse use) DIN Rail Mounting Adapter: A33: With adapter (model: A-33) Standards & Approvals: N: Without CE or UL
Lightning Surge Protector - MDP-24-1/A33/UL Lightning Surge Protector - MDP-24-1/A33/UL MG MODEL #: MDP-24-1/A33/UL (Lightning surge protector for standard signal line & pulse use) DIN Rail Mounting Adapter: A33: With adapter (model: A-33) Standards & Approvals: UL: UL approval, CE marking
Lightning Surge Protector - MDP-24-1/UL Lightning Surge Protector - MDP-24-1/UL MG MODEL #: MDP-24-1/UL (Lightning surge protector for standard signal line & pulse use) DIN Rail Mounting Adapter: blank: Without Standards & Approvals: UL: UL approval, CE marking
MG Multi Power Transducer - M50EXWTU-223-AD4 MG Multi Power Transducer - M50EXWTU-223-AD4

MG MODEL #: M50EXWTU-223-AD4
(PC programmable)

Configuration:
2: Single phase / 2-wire and 3-wire, 3-phase / 3-wire and 4-wire
Input:
2: 480 V AC / CLSE
Clamp-on current sensor is selectable from below.
CLSE (5A, 50A, 100A, 200A, 400A, 600A)
5A is available as CT's secondary.
External Interface:
3: Modbus communication
Input:
Universal
AD4:
100 – 240 V AC / 100 – 240 V DC (universal) (Operational voltage range 85 - 264 V AC, 47 - 66 Hz / 85 - 264 V DC, ripple 10 %p-p max.)

MG Multi Power Transducer - M50XWTU-223-AD4 MG Multi Power Transducer - M50XWTU-223-AD4

MG MODEL #: M50XWTU-223-AD4
(PC programmable)

Configuration:
2: Single phase / 2-wire and 3-wire, 3-phase / 3-wire and 4-wire
Input:
2: 480 V AC / CLSE
Clamp-on current sensor is selectable from below.
CLSE (5A, 50A, 100A, 200A, 400A, 600A)
5A is available as CT's secondary.
External Interface:
3: Modbus communication
Input:
Universal
AD4:
100 – 240 V AC / 100 – 240 V DC (universal) (Operational voltage range 85 - 264 V AC, 47 - 66 Hz / 85 - 264 V DC, ripple 10 %p-p max.)

MG Multi Power Transducer - M5XWTU-111 MG Multi Power Transducer - M5XWTU-111

MG MODEL #: M5XWTU-111
(self-powered, PC programmable, support harmonic distortion)

Configuration:
1: Single phase / 2-wire and 3-wire, 3-phase / 3-wire
Input:
1: 240 V AC / CLSE
Clamp-on current sensor is selectable from below.
CLSE (5A, 50A, 100A, 200A, 400A, 600A)
5A is available as CT's secondary.
External Interface:
1: Analog output -Field selectable
· DC current output: 0 - 20 mA DC
· DC voltage output: -5 - +5 V DC
· DC voltage output: -10 - +10 V DC

MG Multi Power Transducer - M5XWTU-112 MG Multi Power Transducer - M5XWTU-112

MG MODEL #: M5XWTU-112
(self-powered, PC programmable, support harmonic distortion)

Configuration:
1: Single phase / 2-wire and 3-wire, 3-phase / 3-wire
Input:
1: 240 V AC / CLSE
Clamp-on current sensor is selectable from below.
CLSE (5A, 50A, 100A, 200A, 400A, 600A)
5A is available as CT's secondary.
External Interface:
2: Pulse / alarm output

MG Multi Power Transducer - M5XWTU-113 MG Multi Power Transducer - M5XWTU-113

MG MODEL #: M5XWTU-113
(self-powered, PC programmable, support harmonic distortion)

Configuration:
1: Single phase / 2-wire and 3-wire, 3-phase / 3-wire
Input:
1: 240 V AC / CLSE
Clamp-on current sensor is selectable from below.
CLSE (5A, 50A, 100A, 200A, 400A, 600A)
5A is available as CT's secondary.
External Interface:
3: Modbus communication

MG Potentiometer Transmitter - W2MS-AA-R/UL MG Potentiometer Transmitter - W2MS-AA-R/UL

MG MODEL #: W2MS-AA-R/UL
(Space-saving Dual Output Signal Conditioners)

Input:
Potentiometer
Total resistance 100 Ω – 10 kΩ
Output 1:
Current
A: 4 – 20 mA DC (Load resistance 750 Ω max.)
Output 2:
Current
A: 4 – 20 mA DC (Load resistance 350 Ω max.)
Power Input:
DC Power
R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
Response Time (0 – 90 %)
blank: Standard (≤ 0.5 sec.)
Standards & Approvals (must be specified)
UL: UL approval, CE marking

MG Signal Transmitter - M2VS-44-M2/UL MG Signal Transmitter - M2VS-44-M2/UL

MG MODEL #: M2VS-44-M2/UL
(Compact Plug-in, Standard Type)

Input:
Voltage
4: 0 – 10 V DC (Input resistance 1 MΩ min.)
Output:
Voltage
4: 0 – 10 V DC (Input resistance 1 MΩ min.)
Power Input:
AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz)
(90 – 264 V for UL)
Response Time (0 – 90 %)
blank: Standard (≤ 0.5 sec.)
Standards & Approvals (must be specified)
UL: UL approval, CE marking